1,449 research outputs found

    Interface steps in field effect devices

    Full text link
    The charge doped into a semiconductor in a field effect transistor (FET) is generally confined to the interface of the semiconductor. A planar step at the interface causes a potential drop due to the strong electric field of the FET, which in turn is screened by the doped carriers. We analyze the dipolar electronic structure of a single step in the Thomas-Fermi approximation and find that the transmission coefficient through the step is exponentially suppressed by the electric field and the induced carrier density as well as by the step height. In addition, the field enhancement at the step edge can facilitate the electric breakthrough of the insulating layer. We suggest that these two effects may lead to severe problems when engineering FET devices with very high doping. On the other hand steps can give rise to interesting physics in superconducting FETs by forming weak links and potentially creating atomic size Josephson junctions.Comment: 6 pages, 4 figures, submitted to J. Appl. Phy

    Changes in Iron Status Biomarkers with Advancing Age According to Sex and Menopause: A Population-Based Study.

    Get PDF
    BACKGROUND The risk of chronic diseases increases markedly with age and after menopause. An increase in bodily iron following menopause could contribute to this phenomenon of increased risk of chronic diseases. We aimed to investigate how various iron biomarkers change with advancing age, according to sex and menopausal status. METHODS We enrolled community-dwelling individuals with available information on ferritin, transferrin, iron, hepcidin, and soluble transferrin receptor levels from the Prevention of Renal and Vascular Endstage Disease study. The association of the iron biomarkers with age, sex, and menopausal status was investigated with linear regression models. RESULTS Mean (SD) age of the 5222 individuals (2680 women [51.3%], among whom 907 [33.8%] were premenopausal, 529 [19.7%] perimenopausal, and 785 [29.3%] postmenopausal), was 53.4 (12.0) years. Iron biomarkers showed a constant increase in women throughout their life course, in some cases at older ages surpassing values in men who, in turn, showed consistently higher levels of iron status compared to women in most age categories. Ferritin, hepcidin, and transferrin saturation levels were 3.03, 2.92, and 1.08-fold (all p < 0.001) higher in postmenopausal women compared to premenopausal. CONCLUSIONS We found that iron accumulates differently depending on sex, age, and menopausal status. An increased iron status was identified in women, especially during and after menopause

    The possible explanation of electric-field-doped C60 phenomenology in the framework of Eliashberg theory

    Full text link
    In a recent paper (J.H. Schon, Ch. Kloc, R.C. Haddon and B. Batlogg, Nature 408 (2000) 549) a large increase in the superconducting critical temperature was observed in C60 doped with holes by application of a high electric field. We demonstrate that the measured Tc versus doping curves can be explained by solving the (four) s-wave Eliashberg equations in the case of a finite, non-half-filled energy band. In order to reproduce the experimental data, we assume a Coulomb pseudopotential depending on the filling in a very simple and plausible way. Reasonable values of the physical parameters involved are obtained. The application of the same approach to new experimental data (J.H. Schon, Ch. Kloc and B. Batlogg, Science 293 (2001) 2432) on electric field-doped, lattice-expanded C60 single crystals (Tc=117 K in the hole-doped case) gives equally good results and sets a theoretical limit to the linear increase of Tc at the increase of the lattice spacing.Comment: latex2e, 6 pages, 7 figures, 1 table, revised versio

    Recovering long-term aerosol optical depth series (1976–2012) from an astronomical potassium-based resonance scattering spectrometer

    Get PDF
    A 37-year long-term series of monochromatic aerosol optical depth (AOD) has been recovered from solar irradiance measurements performed with the solar spectrometer Mark-I, deployed at Izaña mountain since 1976. The instrument operation is based on the method of resonant scattering, which affords wavelength absolute reference and stability (long-term stability and high precision) in comparison to other instruments based purely on interference filters. However, it has been specifically designed as a reference instrument for helioseismology, and its ability to determine AOD from transmitted and scattered monochromatic radiation at 769.9 nm inside a potassium vapour cell in the presence of a permanent magnetic field is evaluated in this paper. Particularly, the use of an exposed mirror arrangement to collect sunlight as well as the Sun–laboratory velocity dependence of the scattered component introduces some important inconveniences to overcome when we perform the instrument's calibration. We have solved this problem using a quasi-continuous Langley calibration technique and a refinement procedure to correct for calibration errors as well as for the fictitious diurnal cycle on AOD data. Our results showed similar calibration errors retrieved by means of this quasi-continuous Langley technique applied in different aerosol load events (from 0.04 to 0.3), provided aerosol concentration remains constant throughout the calibration interval.The AERONET sun photometers at Izaña have been calibrated within AERONET-Europe TNA supported by the European Community-Research Infrastructure Action under the FP7 “Capacities” specific programme for Integrating Activities, ACTRIS grant agreement no. 262254. The GAW-PFR network for AOD at WMO-GAW global observatories has been implemented by the World Optical Depth Research and Calibration Center (WORCC). Mark-I operation was supported by the Spanish National Plan of Research and Development under grant no. AYA2012–17803

    Crystal Structures and Electronic Properties of Haloform-Intercalated C60

    Full text link
    Using density functional methods we calculated structural and electronic properties of bulk chloroform and bromoform intercalated C60, C60 2CHX3 (X=Cl,Br). Both compounds are narrow band insulator materials with a gap between valence and conduction bands larger than 1 eV. The calculated widths of the valence and conduction bands are 0.4-0.6 eV and 0.3-0.4 eV, respectively. The orbitals of the haloform molecules overlap with the π\pi orbitals of the fullerene molecules and the p-type orbitals of halogen atoms significantly contribute to the valence and conduction bands of C60 2CHX3. Charging with electrons and holes turns the systems to metals. Contrary to expectation, 10 to 20 % of the charge is on the haloform molecules and is thus not completely localized on the fullerene molecules. Calculations on different crystal structures of C60 2CHCl3 and C60 2CHBr3 revealed that the density of states at the Fermi energy are sensitive to the orientation of the haloform and C60 molecules. At a charging of three holes, which corresponds to the superconducting phase of pure C60 and C60 2CHX3, the calculated density of states (DOS) at the Fermi energy increases in the sequence DOS(C60) < DOS(C60 2CHCl3) < DOS(C60 2CHBr3).Comment: 11 pages, 7 figures, 4 table

    Low-Energy Effective Hamiltonian and the Surface States of Ca_3PbO

    Full text link
    The band structure of Ca_3PbO, which possesses a three-dimensional massive Dirac electron at the Fermi energy, is investigated in detail. Analysis of the orbital weight distributions on the bands obtained in the first-principles calculation reveals that the bands crossing the Fermi energy originate from the three Pb-p orbitals and three Ca-dx2y2 orbitals. Taking these Pb-p and Ca-dx2y2 orbitals as basis wave functions, a tight-binding model is constructed. With the appropriate choice of the hopping integrals and the strength of the spin-orbit coupling, the constructed model sucessfully captures important features of the band structure around the Fermi energy obtained in the first-principles calculation. By applying the suitable basis transformation and expanding the matrix elements in the series of the momentum measured from a Dirac point, the low-energy effective Hamiltonian of this model is explicitely derived and proved to be a Dirac Hamiltonain. The origin of the mass term is also discussed. It is shown that the spin-orbit coupling and the orbitals other than Pb-p and Ca-dx2y2 orbitals play important roles in making the mass term finite. Finally, the surface band structures of Ca_3PbO for several types of surfaces are investigated using the constructed tight-binding model. We find that there appear nontrivial surface states that cannot be explained as the bulk bands projected on the surface Brillouin zone. The relation to the topological insulator is also discussed.Comment: 11 page

    Computationally-Optimized Bone Mechanical Modeling from High-Resolution Structural Images

    Get PDF
    Image-based mechanical modeling of the complex micro-structure of human bone has shown promise as a non-invasive method for characterizing bone strength and fracture risk in vivo. In particular, elastic moduli obtained from image-derived micro-finite element (ÎźFE) simulations have been shown to correlate well with results obtained by mechanical testing of cadaveric bone. However, most existing large-scale finite-element simulation programs require significant computing resources, which hamper their use in common laboratory and clinical environments. In this work, we theoretically derive and computationally evaluate the resources needed to perform such simulations (in terms of computer memory and computation time), which are dependent on the number of finite elements in the image-derived bone model. A detailed description of our approach is provided, which is specifically optimized for ÎźFE modeling of the complex three-dimensional architecture of trabecular bone. Our implementation includes domain decomposition for parallel computing, a novel stopping criterion, and a system for speeding up convergence by pre-iterating on coarser grids. The performance of the system is demonstrated on a dual quad-core Xeon 3.16 GHz CPUs equipped with 40 GB of RAM. Models of distal tibia derived from 3D in-vivo MR images in a patient comprising 200,000 elements required less than 30 seconds to converge (and 40 MB RAM). To illustrate the system's potential for large-scale ÎźFE simulations, axial stiffness was estimated from high-resolution micro-CT images of a voxel array of 90 million elements comprising the human proximal femur in seven hours CPU time. In conclusion, the system described should enable image-based finite-element bone simulations in practical computation times on high-end desktop computers with applications to laboratory studies and clinical imaging

    Estimation of trabecular bone parameters in children from multisequence MRI using texture-based regression

    Get PDF
    PURPOSE: This paper presents a statistical approach for the prediction of trabecular bone parameters from low-resolution multisequence magnetic resonance imaging (MRI) in children, thus addressing the limitations of high-resolution modalities such as HR-pQCT, including the significant exposure of young patients to radiation and the limited applicability of such modalities to peripheral bones in vivo. METHODS: A statistical predictive model is constructed from a database of MRI and HR-pQCT datasets, to relate the low-resolution MRI appearance in the cancellous bone to the trabecular parameters extracted from the high-resolution images. The description of the MRI appearance is achieved between subjects by using a collection of feature descriptors, which describe the texture properties inside the cancellous bone, and which are invariant to the geometry and size of the trabecular areas. The predictive model is built by fitting to the training data a nonlinear partial least square regression between the input MRI features and the output trabecular parameters. RESULTS: Detailed validation based on a sample of 96 datasets shows correlations >0.7 between the trabecular parameters predicted from low-resolution multisequence MRI based on the proposed statistical model and the values extracted from high-resolution HRp-QCT. CONCLUSIONS: The obtained results indicate the promise of the proposed predictive technique for the estimation of trabecular parameters in children from multisequence MRI, thus reducing the need for high-resolution radiation-based scans for a fragile population that is under development and growth

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE
    • …
    corecore